CDQHZ - 896 0288 KODAK K-LAB FIRST DEVELOPER, PART A, PROCESS K-14M

  • MSDS: CDQHZ
  • Manufacturer: EASTMAN KODAK COMPANY
  • Product Name: 896 0288 KODAK K-LAB FIRST DEVELOPER, PART A, PROCESS K-14M
  • National Stock Number: 6750-00D006395
Product Identification

Product ID:896 0288 KODAK K-LAB FIRST DEVELOPER, PART A, PROCESS K-14M
MSDS Date:09/20/1996
FSC:6750
NIIN:00D006395
Kit Part:Y
MSDS Number: CDQHZ

Responsible Party
EASTMAN KODAK COMPANY
343 STATE STREET
ROCHESTER, NY 14650
US

Emergency Phone: 716-722-5151

Info Phone: 716-722-5151

Cage: 19139

Contractor
EASTMAN KODAK CO US CUSTOMER SERVICE/GOVERNMENT SALES
ROCHESTER, NY 14650-3129 US

Telephone: 800-828-6203

Cage: 5K871

Ingredients

WATER

CAS: 7732-18-5

RTECS: ZC0110000

Fraction By Weight: 85-90%


SODIUM SULFITE

CAS: 7757-83-7

RTECS: WE2150000

Fraction By Weight: 5-10%


SODIUM CARBONATE

CAS: 497-19-8

RTECS: VZ4050000

Fraction By Weight: 1-5%


SODIUM BICARBONATE

CAS: 144-55-8

RTECS: VZ0950000

Fraction By Weight: <1%


HYDROQUINONE (SARA 302/313) (CERCLA)

CAS: 123-31-9

RTECS: MX3500000

Fraction By Weight: <1%

OSHA PEL 2 MG/M3

ACGIH TLV: 2 MG/M3; 9596

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALE-EXPECTED TO BE A LOW HAZARD FOR
RECOMMENDED HANDLING. EYE-CAUSES IRRITATION. SKIN-CAUSES
IRRITATION. MAY CAUSE ALLERGIC SKIN REACTION. INGESTION-EXPECTED TO
BE A LOW INGESTION HAZARD.
Explanation of Carcinogenicity:NOT CARCINOGENIC.
Effects of Overexposure:NONE SPECIFIED BY MANUFACTURER.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHALE-IF SYMPTOMATIC, MOVE TO FRESH AIR. GET MEDICAL
ATTENTION IF SYMPTOMS PERSIST. EYE-IMMEDIATELY FLUSH WITH PLENTY OF
WATER FOR 15 MIN. GET MEDICAL ATTENTION. SKIN-IMMEDIATELY REMOVE
CONTAMINATED CLOTHING & SHOES & WASH WITH SOAP & WATER. GET
EMDICAL ATTENTION. INGEST-DRINK 1-2 GLASSES OF WATER. SEEK MEDICAL
ATTENTION. NEVER GIVE ANYTHING BY MOUTH TO AN UNCONSICOUS PERSON.

Fire Fighting

Flash Point:NONE
Extinguishing Media:USE AGENT APPROPIATE FOR SURROUNDING FIRE.
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS AND
PROTECTIVE CLOTHING. FIRE OR EXCESSIVE HEAT MAY PRODUCE HAZARDOUS
DECOMPOSITION PRODUCTS.
Unusual Fire/Explosion Hazard:NONE

Accidental Release

Spill Release Procedures:FLUSH TO SEWER WITH LARGE AMOUNTS OF WATER.
OTHERWISE, ABSORB SPILL WITH VERMICULITE OR OTHER INERT, THEN PALCE
IN A CONTAINER FOR CHEMICAL WASTE. CLEAN SURFACE THOROUGHLY TO
REMOVE RESIDUAL CONTAMINA TION.

Handling

Handling and Storage Precautions:KEEP CONTAINER CLOSED. KEEP AWAY FROM
INCOMPATIBLE SUBSTANCES.
Other Precautions:AVOID CONTACT WITH EYES, SKIN AND CLOTHING. USE WITH
ADEQUATE VENTILATION. WASH THOROUGHLY AFTER HANDLING.NONE

Exposure Controls

Respiratory Protection:NONE SHOULD BE NEEDED.
Ventilation:GOOD GENERAL VENTILATION (TYPICALLY 10 AIR CHANGES/HR)
SHOULD BE USED. VENTILATION RATES SHOULD BE MATCHED TO CONDITIONS
Protective Gloves:WEAR IMPERVIOUS GLOVES
Eye Protection:SAFETY GLASSES WITH SIDE SHIELD
Other Protective Equipment:EYE BATH, WASHING FACILITIES, SAFETY SHOWER.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING AND BEFORE
EATING, DRINKING OR SMOKING. LAUNDER CONTAMINATED CLOTHING BEFORE
REUSE.
Supplemental Safety and Health
NONE

Chemical Properties

HCC:B3
Boiling Pt:B.P. Text:>212F,>100C
Vapor Pres:18
Vapor Density:0.6
Spec Gravity:1.110
pH:10.1
Solubility in Water:COMPLETE
Appearance and Odor:LIQUID, COLORLESS, ODORLESS.
Percent Volatiles by Volume:85-90

Stability

Stability Indicator/Materials to Avoid:YES
STRONG ACIDS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NONE

Disposal

Waste Disposal Methods:DISCHARGE, TREATMENT OR DISPOSAL MUST BE MADE IN
ACCORDANCE WITH APPLICABLE FEDERAL, STATE AND LOCAL REGULATIONS.
FLUSH TO SEWER WITH LARGE AMOUNTS OF WATER.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.